+ | ====== Extruder ====== | ||
+ | |||
+ | - Use calipers or a ruler to measure 100mm along the filament from the extruder opening and make a mark on the filament with a permanent marker | ||
+ | - Use calipers or a ruler to measure 110mm along the filament from the extruder opening and make a mark on the filament with a permanent marker | ||
+ | - Use calipers or a ruler to measure 120mm along the filament from the extruder opening and make a mark on the filament with a permanent marker | ||
+ | - Heat the nozzle to 200C | ||
+ | - Move the Z axis to 50mm | ||
+ | - Extrude 100mm of filament | ||
+ | - Use calipers or a ruler to measure from the extruder opening to the first visible mark | ||
+ | - If all three marks are visible then it is under extruding so subtract the value measured from 100 to get the actual extruded length | ||
+ | - If only two of the marks are visible then it is over extruding so subtract the value measured from 110 to get the actual extruded length | ||
+ | - If only one of the marks are visible then it is really over extruding so subtract the value measured from 120 to get the actual extruded length | ||
+ | - Calculate the new extruder steps | ||
+ | - New Steps = (100 / Actual Length) x Current Steps | ||
+ | - Change the steps value | ||
+ | |||
+ | ====== X And Y ====== | ||
+ | |||
+ | - Clip a piece of paper to the build plate | ||
+ | - Move the X carriage to a location over the paper | ||
+ | - Attach a pencil to the X carriage with a rubber band | ||
+ | - Move the X carriage 100mm in the X direction | ||
+ | - Move the X carriage 100mm in the Y direction | ||
+ | - Move the build plate 50mm in the Z direction | ||
+ | - Measure the length of both lines with a ruler or calipers | ||
+ | - Calculate the new steps value | ||
+ | - New Steps = (100 / Measured) x Current Steps | ||
+ | - Change the steps value | ||
+ | |||
+ | This procedure is based on [[https:// | ||
+ | |||
+ | ====== Temperature ====== | ||
+ | |||
+ | Follow the steps for [[https:// | ||
+ | |||
+ | ====== Retraction ====== | ||
+ | |||
+ | Follow the steps for [[https:// | ||
+ | |||
+ | ====== Flow Rate ====== | ||
+ | |||
+ | Follow the steps for [[https:// | ||